4. Relay output 220V/3A of two ways control
Character:
* Power Supply: 24VDC/220VAC
* Output: 2 relay for 2 setpoint, 4-20mA in option
* Two independently adjustable set points with fixed dead band.
* Ingress protection: IP66
* Dead band: narrow, fixed.
* Operating Temperature: -30~80℃
* Process connections: M20x1.5 Male thread or others.
* Process fluid: water, gas, oil
* Range: 0-1.0 bar****35.00bar max
* Factory adjusted set points:
* Min. Set point = 380 mbar (decreasing)
* Max. Set point = 2 bar to 35bar (increasing)
* Accuracy: ≤0.5%F.S
* Overload Capacity: 150%F.S.
* Response Time: <30ms
* Stability: <0.1%/year
* Display: 0.56" Nixie Tube
* Display Range: -1999~9999
* Media Temperature: -40~150℃(Heat radiator must be used if Media temperature over 80℃)
* Relative Humidity: 0-90%
Contact: Alvin
* * * * * * *
Email: sales@ayite.net
Add: No.116-122, KWOK SHUI ROAD, Kwai Chung Industry Center, HongKong